    Flexural strength of concrete prism strengthened using CFRP with modified mortar

    Get PDF
    Reinforced concrete (RC) is a good durable material that commonly used in construction compared to others. However, reinforced concrete structures may be damaged and are suffering from various deteriorations because of overloading and an inadequacy of design which may be attributed to cracks, spalling, large deflection, and more. Hence, it is essential to find repair and strengthening techniques of deteriorated concrete structures not only suitable in terms of the economy, but also to use them for their intended service life

    Flexural Behaviour of Reinforced Concrete Beams with Openings Strengthened by Textile Reinforced Concrete (TRC) Wrap

    Get PDF
    This paper presents an experimental study of reinforced concrete beams with circular and square openings at the flexure zone. Selected beams were strengthened using Textile Reinforced Concrete (TRC) wraps. A total of six beam specimens measuring 250 mm (height) x 200 m (width) x 1700 mm (length) were cast using high strength concrete with a compressive strength of 64 N/mm2. The beams tested consisted of a solid control beam, unstrengthened concrete beams with openings and strengthened concrete beams with openings. The effect of circular and square openings on the flexure zone of concrete beams was investigated. All the beams were simply supported and tested up to failure under four-point loading. From the test results, it was found that the presence of openings at the flexure zone significantly reduces the strength and stiffness of the beams. The use of TRC wrap around the beam openings increases the ultimate capacity and stiffness of the beams. In addition, it also reduces excessive vertical cracks and deflection in beams considerably compared to unstrengthened concrete beams with openings

    Nonlinear finite element analysis of reinforced concrete beams strengthened with textile fine grained mortar

    Get PDF
    Nowadays, there was an increasing need of repairing and upgrading the reinforced concrete (RC) structure due to the deterioration of the structure. The fibre reinforced polymer (FRP) was commonly used for structural retrofitting purposes. However, owing to the debonding of the FRP from the concrete substrate and high cost of epoxy, it was gradually replaced with textile fine grained mortar (TFGM) nowadays. The TFGM system has been widely used in the construction field nowadays to repair the structure. Our study focus on the strain performances of the concrete surface, steel reinforcement and the textile itself. There were many proven experimental results showing that the TFGM was more effective than the other strengthening method such as FRP plate method. The experimental work done by previous researcher on investigation of strain performances of the concrete surface, steel reinforcement and the textile itself which consists of eleven (11) RC beams with dimension 150 x 200 x 2500 mm. The RC beams were strengthened with FGM and TFGM with 4 layers. The investigation continued with the finite element (FE) strain performance analysis with using Advanced Tool for Engineering Nonlinear Analysis (ATENA) software. The strain of the concrete surface, steel reinforcement and the textile were measured at a mid-point of RC beam. Then, the results of the finite element analysis software ATENA compared against the experimental results. The strain performances of the concrete and steel reinforcement improved noticeably when the number of layers of textile reinforcement used increased

    Study on IBS Cooling Panel Wall System with Difference Types of Cooling Mediums

    Get PDF
    Global warming has caused worldwide average surface temperature to rise about 0.74oC during the past 100 years, which is partly aggravated by air-conditioning that releases chlorofluorocarbons (CFCs) and forming a vicious cycle.  This paper proposes a cooling house system that can promote thermal comfort in buildings without air-conditioning.  The cooling panel wall forms a part of an Integrated Building System (IBS), and is essentially made of tubes filled with either water or glycerin as the coolant.  Target strength for the panel wall was designed based on the Malaysian Standard (MS) while the building ventilation system followed the American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE) standard. The results are reported based on indoor and outdoor temperature difference together with relative humidity to identify the best performing house model and also coolant.  The outcome of this research is expected to add value to heritage house design concepts with a better promotion of air flow and circulation in the building, without over-usage of natural resources and higher building cost to achieve the same objective.&nbsp

    The effect of curing conditions on the strength of masonry blocks incorporating palm oil fuel ash

    Get PDF
    Palm Oil Fuel Ash (POFA) is a by-product of the palm oil industry that is often disposed at landfills. In oil palm-producing countries such as Malaysia, Indonesia and Thailand, the high amount of POFA waste disposal is undoubtedly an environmental problem that needs to be overcome to contribute towards zero-carbon emissions by 2050. This paper presents the incorporation of POFA as a partial cement replacement in the production of concrete masonry blocks – a common building material in developing countries. In this study, the cement con�tent by weight of a conventional concrete masonry block was replaced incremen�tally at 10% interval until 30% with ground POFA. The specimens were either cured in water or left dry and tested after 28 days of curing for density, compressive strength and water absorption rate based on standard testing requirements. A general observation has been taken note on the superior results of water-cured masonry blocks with up to 20% POFA content. The results of this study is antic�ipated to add value to the present knowledge bank on incorporating waste material into sustainable building material research and development. In general, POFA is a highly potential replacement for cement, but further studies need to be done to ensure consistency in performance and for industrial application

    Assessing generation y readiness to meet job demand: A case study of internship students at large government invested company

    Get PDF
    This paper will discuss the survey that was carried out in Large Government Invested Company.Every year, the organization accepted more than 100 internship student placement ranging from various public and private higher learning institutions (HLI) in the country. Those internship students are categorized as generation y.This generation will take over current job position when the baby boomer generation reaches their retirement ages.Survey was conducted to access the readiness of internship students towards job demand.Data were collected through online survey that was developed on the Microsoft SharePoint Portal.The result of the survey will be used to create a profile of future recruitment and developing new working surrounding for generation y in the organization

    Compressive Strength and Water Absorption of Sand Cement Brick that Incorporated with Construction Tiles Waste

    Get PDF
    Ceramic Tiles Waste (CTW) is one of the major sources of construction and demolition (C&D). Recycling the C&D waste is one of the most effective ways to develop sustainable building elements. In this study, the CTW were used as a partial sand replacement in sand cement brick. The percentages replacement of CTW are 0%, 10%, 20%, 30%, 40% and 50% by mass of the sand with mix design ratio of 1:3 and 0.6 water cement ratio. All the bricks were curing up to 90 days. The density, compressive strength and water absorption of sand cement bricks were also determined for its mechanical and durability performance. The experimental results reveal that the optimum replacement of CTW in sand cement brick is in range of 10% to 40% that give a good performance in compressive strength. The compressive strength of sand cement bricks increases in range of 10.17% up to 30.82% for each stage of curing days from 7 days up to 90 days. Meanwhile, the percentage of water absorption of sand cement bricks at 28 days up to 90 days of curing are below 12% as per stated in ASTM C90.

    Shear Capacity of Reinforced Concrete Beam with an Opening Retrofit Using Steel Fiber and Metakaolin

    Get PDF
    This study presents the experimental work of reinforced concrete beam with opening at shear zone and added with steel fibre and metakaolin to increase the shear capacity of the beam. A total of five (5) beams were casted and tested under four-point bending test. One beam served as the control specimen, two beams were beams with one and two opening respectively while the other two beams were beams with added steel fibre and metakaolin. The type of steel fibre used was a hooked-end steel fibers with the dimensions of 0.9mm in diameter, 60mm in length, and 0.5% of steel fiber was added by volume of beam, and 5% of metakaolin by volume of beam were used. From the experimental results, it was found that the two beams with added steel fibre and metakaolin shows an increase in shear capacity compared with the beams with opening without the steel fibre and metakaolin. The highest shear force recorded was 79.11 kN (beams with added steel fibre and metakaolin) which shows an increase for about 54.3 % compared with the same beam with opening without added steel fibre and metakaolin

    Fresh Properties and Compressive Strength of 3D Printing Concrete Containing GGBS as Partial Cement Replacement

    Get PDF
    3D printed concrete is a particular mix of concrete that has been specially prepared to flow easily through the printing nozzle. The foundations of 3D printed concrete constructions are stacked, with each layer put on top of a preceding layer of pumped concrete. Despite its potential, the construction industry has been confronted with several material issues. The cement replacement in the concrete has also been intensively studied, but in 3D printed concrete, this matter has not been seen clearly. It still cannot be seen whether the cement replacement produces a good result for the 3D printed concrete. This research investigated the fresh characteristics and compressive strength of 3D printed concrete using GGBS as a partial cement replacement in the mixture. In addition, the optimal proportion of GGBS as a partial cement replacement in 3D printed concrete is also evaluated. In this study, the fresh properties of 3D printing were examined by a flow table test, a buildability test, and an extrudability test, while compression strength was assessed for the mechanical properties. The percentage of GGBS used will vary from 20% to 50% with a 10% increment by weight of cement, and the water-cement ratio was fixed at 0.5. The cube specimen for the compression test was 50 mm x 50 mm x 50 mm and was cured for 7 and 28 days. The findings show that the flowability of this 3D printed concrete increased as the percentage of GGBS increased. All of the specimens also passed the buildability and extrudability tests. The compressive strength of this 3D printed also increased as the percentage increased, but it decreased back at 50% GGBS replacement. Overall, this experiment shows that 40% GGBS replacement is the optimum proportion as cement replacement in 3D printed concrete as it shows the highest compressive strength, which is 57.3 MPa

    Thermal Conductivity Of Lightweight Concrete Block With Various Cooling Agent

    Get PDF
    Energy was the important sources to human life. Due to increases energy demand in daily life, the energy consumption was increase day by day because of the heat load from solar radiation and heat produced by people. Toward sustainable development, this research was carried out to develop a lightweight concrete (LWC) block with various cooling agent such as glycerine, propylene glycol, coconut shell and gypsum powder. Six lightweight concrete (LWC) block with the size 250mm (L) × 250mm (W) × 100mm (T) were tested for thermal conductivity value.  From the experimental result, it shows that lightweight concrete (LCW) block with various cooling agent obtained thermal conductivity value of 0.17W/mK - 0.36W/mK lower than thermal conductivity value for normal lightweight concrete (0.8W/mK) depending on concrete density.  The lightweight concrete (LCW) block with cooling agent having low thermal conductivity value will reduce energy consumption in building